Prefabricated substations
Packages combining MV switching, transformation and LV distribution in the selected configuration.
Prefabricated substations and coordinated conversion and step-up equipment, with agreed supply interfaces.

Factory-assembled packages combine electrical stages. Agree what is included, tested together and completed on site.
Packages combining MV switching, transformation and LV distribution in the selected configuration.
Coordinate storage converters, transformers and switching interfaces.
Match the package to the battery, facility and grid connection. Agree equipment and integration responsibilities.
Confirm ratings, compliance evidence and availability for the selected model.
| Parameter | Family / selection basis | Project consideration |
|---|---|---|
| Published power range | 0.5–3.75 MW | Converter and transformer capacity are selected together. |
| Electrical interfaces | 800–1,500 V DC; 400 / 690 V AC | Confirm the battery voltage window and converter pairing. |
| Grid connection | 10 kV; 35 kV option | Includes dry-type step-up and MV switching; battery system is separate. |
Selected containerised variant in manufacturer material reviewed August 2026. These ratings do not apply to every packaged substation. Grid-code acceptance remains project-specific.
Request the model datasheet ↗| Parameter | Family / selection basis | Project consideration |
|---|---|---|
| Package boundary | Included equipment and external terminals | Document converter, transformer, switchgear, auxiliary and control scope. |
| Electrical arrangement | Connection voltages, capacity and fault duty | Coordinate with the site design and point of connection. |
| Enclosure & environment | Installation setting and operating conditions | Confirm footprint, ventilation, access, corrosion protection and maintainability. |
| Controls | BMS, PCS, EMS and site/network interfaces as applicable | Agree integration ownership, protocols and acceptance criteria. |
| Factory acceptance | Tests on included equipment and assembled interfaces | Distinguish equipment testing from complete system acceptance. |
| Site responsibilities | Foundations, cabling, earthing, installation and commissioning | Only explicitly agreed works belong in the supply package. |
Coordinate the conversion and step-up stage around the selected battery system.
Bring transformation and distribution together where a packaged approach suits the site.
Assess the voltage, control and connection requirements alongside the generation architecture.
No. The quote defines included site works and responsible parties.
No. Each relevant item and the assembled system need evidence for their configuration and application.
Tell us what you’re planning.
Technical details can follow.